Security Systems and Home Alarms

Customer Support Center

System Operation Instructions and Manuals :
DSC 1555/5010

Manuals Available :
User Manual - English :
User Manual - Spanish :

Quick Reference Sheet :

Arming

Away Mode – used when everyone is leaving the house.  Arms perimeter and interior devices

  • Enter 4 digit code and exit house

Stay Mode – used when someone is staying in the house.  Arms perimeter but not motion detectors

  • Enter 4 digit code and remain in the house

Disarming

  • Enter the 4 digit code when entering the house or if the system is in alarm.
  • Press # then reenter the code if a wrong key is pressed while trying to enter the code.

Panic Buttons

  • Hold the panic button down 3 to 5 seconds to activate
  • If there are two buttons side by side for each panic, press and hold both buttons together for 3-5 seconds to activate

Changing Codes

Change Master Code

  • Press * + 5 + current code + 1 + new code + #

Add User Codes

  • Press * + 5 + master code + user code number (2-5) + new code + #
  • Example to add an additional code : * 5 1234 2 0000 #

Deleting user code

  • Press * + 5 + master code + two digit user number (2-5) + * * * * + #
  • Example to remove an additional code : * 5 1234 2 * #

Bypassing Zones

When arming, arms everything but zone(s) bypassed. The bypass or system light will stay on. To arm system without motions if you are leaving, bypassing will be required

  • Press * + 1 + zone to bypass + #
  • Example to bypass zone 3 : *1 3 # then arm the system

Chime Mode

When chime mode is enabled, the opening of any door or window will cause a chime noise at the keypads

  • Press * + 6 + master code + 6 # to activate / deactivate.

Duress Code

An alternate code that disarms the system but also sends a silent signal to the central station. * if programmed